3 Phase Transformer-less UPS

MAKPOWER Technology's new transformer-less UPS, the EXODUS Series PXL (10 - 200KVA), The system is best in class for its small footprint and high efficiency. Exodus PXL (10-200KVA) is versatile in its configurations and offers a variety of options. As a result, it is an excellent power protection solution for small and medium-sized critical applications where power consumption, available space, and reliability are critical parameters.

Features

The Exodus PXL Series is based on an extremely effective
transformer-less double conversion technology, resulting
in the lowest OPEX in its category. Top of the line in terms
of energy consumption; the system has an extremely low
Total Cost of Ownership (TCO).

  • Compact foot-print, with integrated batteries or
    isolation transformer up to 80 kVA
  • 3-level IGBT technology
  • Transformer-less architecture
  • AC/AC efficiency up to 95.6 % (VFI) and 98 % in VFD*
  • Input PF > 0.99 and THDi < 3 %*
  • Output PF up to unity (without derating)
  • Up to 8 units in parallel connection
  • Static and maintenance bypass switches included
  • Back-feed protection included
  • Cold start (battery start) function
  • 10″ touch screen display
  • Wide range of options

Specifications

Technical Specifications
Models(KVA)10, 15, 20, 30, 40, 60, 80, 100, 120, 160, 200
Nominal active power up to 40°C (kW)9, 13.5, 18, 27, 36, 54, 72, 100, 120, 160, 200
Dimensions W x D x H (mm) 828 x 250 x 868, 828 x 360 x 868, 850 x 442 x 1200
Weight without batteries/transformer (kg)57, 63, 64, 71, 73, 83, 143, 147, 152, 200, 230
Mains Input Line (Rectifier)
Phase3Ph + N + G
Nominal voltage (V)380/400/ 415
Voltage range (V)-20% / +15%
Frequency (Hz)50 / 60
Frequency range (Hz)40 – 70
Power factor>0.99
Input THDi (at rated voltage and THDv <0.5%)<3% (with full linear load)
Bypass Input Line
Nominal bypass input voltage (V)380/400/415
Bypass input voltage range± 20% (with full load)
Bypass input frequency (Hz)50/60
Bypass frequency range (Hz)Nominal: ± 3 % (adjustable)
Overload capacity through bypass lineUp to 150 % continuously Up to 180% @ 1min Up to 1000% @ 100ms
Output Line(inverted)
Voltage (V)380 / 400/ 415
Output THDv (according to IEC EN 62040-3)<2 % (with linear load); < 5% (with non linear load)
Transient response± 2% for dynamic step load (20 % – 100% – 20%)
Transient recovery (after step load)<20ms
Output PF (up to 40°C)Up to 0.9 , Up to 1
Crest factor 3:1
Frequency (Hz)50/60
Slew rate (Hz/s)0.5 to 5 (adjustable)
Overload capacity through inverter lineUp to 105 % for long time operation, <110% with transfer to bypass after 60 minutes, <125% with transfer to bypass after 10 minutes, <150% with transfer to bypass after 60 seconds, >150% with transfer to bypass after 100 ms
Short circuit current (through inverter line)>180% with output VAC < 22V rms (O/P current is limited for max. 180ms; if continues, the UPS will shut down)
AC/AC efficiency in VFI @ nominal linear load>93.0% ,>93.0% ,>93.0% ,>93.3% ,>93.3% ,>94.5% ,>94.8% ,>94.8% ,>95.6 % ,>94.5% ,>95.3 %
AC/AC efficiency in VFD>98% (at nominal load)
Battery Line
Nominal DC voltage (VDC)±120V, ±192V - ±240V
Quantity of lead acid batteries (12V each)16-20 blocks (optional), 32-50 blocks (optional)
Recharge power20% of nominal power
User Interface
DisplayLCD Touch Screen Display ( 7''-10'') (optional)
Standard communication portsRS232, USB
Optional communication portsSNMP, dry contact relay card, Modbus
General
Protection degreeIP20 (standard); other values upon request (up to IP41)
ColorRAL 9005
Operating temperature (°C)0 to 40
Storage temperature (°C)-15 to 70
Relative humidity0 to 95 %
Altitude (above sea level) (m)< 1000 (with power derating of 0.5 % every 100m up to 3000m, according to IEC EN 62040-3)
Noise at 1m distance (dB)<57, <62, <64, <68
Standards And Certifications
Marking and certificationsCE
SafetyIEC EN 62040-1
EMCIEC EN 62040-2
Test and performanceIEC EN 62040-3